March 2011 |

Specifications
| Processor |
AMD Phenom™ II X4 |
| Model |
955 |
| OPN Tray |
HDX955FBK4DGM |
| OPN PIB |
HDX955FBGMBOX |
| Operating Mode 32 Bit |
Yes |
| Operating Mode 64 Bit |
Yes |
| Revision |
C3 |
| Core Speed (MHz) |
3200 |
| Voltages |
0.850-1.40V |
| Max Temps (C) |
62'C |
| Wattage |
125 W |
| Virtualization |
Yes |
| L1 Cache Size (KB) |
128 |
| L1 Cache Count |
4 |
| L2 Cache Size (KB) |
512 |
| L2 Cache Count |
4 |
| L3 Cache Size (KB) |
6144 |
| CMOS |
45 nm SOI |
| Socket |
AM3 |
| AMD Business Class |
No |
| Black Edition |
Yes |
Click here to return
|
|
|
March 2011 |

Specifications
| Processor |
AMD Phenom™ II X6 |
| Model |
1055T |
| OPN Tray |
HDT55TFBK6DGR |
| OPN PIB |
HDT55TFBGRBOX |
| Operating Mode 32 Bit |
Yes |
| Operating Mode 64 Bit |
Yes |
| Revision |
E0 |
| Core Speed (MHz) |
2800 |
| Voltages |
1.125-1.40V |
| Max Temps (C) |
62 |
| Wattage |
125 W |
| Virtualization |
Yes |
| L1 Cache Size (KB) |
128 |
| L1 Cache Count |
6 |
| L2 Cache Size (KB) |
512 |
| L2 Cache Count |
6 |
| L3 Cache Size (KB) |
6144 |
| CMOS |
45nm SOI |
| Socket |
AM3 |
| AMD Business Class |
No |
| Black Edition |
No |
Click here to return
|
|
|
March 2011 |

Specifications
| Processor |
AMD Athlon™ II X2 |
| Model |
255 |
| OPN Tray |
ADX255OCK23GM |
| OPN PIB |
ADX255OCGMBOX |
| Operating Mode 32 Bit |
Yes |
| Operating Mode 64 Bit |
Yes |
| Revision |
C3 |
| Core Speed (MHz) |
3100 |
| Voltages |
0.85-1.40V |
| Max Temps (C) |
74 |
| Wattage |
65 W |
| Virtualization |
Yes |
| L1 Cache Size (KB) |
128 |
| L1 Cache Count |
2 |
| L2 Cache Size (KB) |
1024 |
| L2 Cache Count |
2 |
| L3 Cache Size (KB) |
|
| CMOS |
45nm SOI |
| Socket |
AM3 |
| AMD Business Class |
No |
| Black Edition |
No |
Click here to return
|
|
|
March 2011 |

GENERAL INFORMATION
|
 |
| Model Type |
DC UPS |
 |
| Model Name |
DC 12V UPS |
 |
 |
INPUT
|
 |
| Input Voltage |
AC 110V or 220V +/-25% at line input (optional: 86V~276V at line input) |
 |
| Input Frequency |
50 or 60 Hz |
 |
| Input LED |
Green LED always light |
 |
 |
OUTPUT
|
 |
| Output Capacity |
30W |
 |
| Output No Of Sockets |
Two DC UPS Sockets |
 |
| Output Transfer Time |
0 millisecond |
 |
| Outlet LED |
Green LED flash every 3 seconds |
 |
 |
PROTECTION
|
 |
| Protection Unit Input |
Fuse for overload & short circuit protection |
 |
| Protection Overload Protection |
UPS automatic shutdown if overload |
 |
| Protection Short Circuit |
UPS output cut off immediately |
 |
 |
BATTERY
|
 |
| Battery Type |
Sealed lead acid battery, free-maintenance with 3-6 year typical lifetime |
 |
| Battery Protection |
Shutdown when battery voltage drops below 10V, Over discharge protection, short circuit protection by fuse |
 |
| Battery Run Time |
90 - 120 minutes |
 |
 |
BACKUP TIME
|
 |
| Battery Recharge Time |
4 hours |
 |
 |
PHYSICAL
|
 |
| Physical Weight kgs |
3 |
 |
| Physical Weight lbs |
(6.6lb) |
 |
| Physical Dimension mm |
267x155x64 |
 |
| Physical Dimension inch |
(10.5 |
 |
 |
 |
ALARM
|
 |
| Alarm Battery Low |
Rapid beeping sound every 3 seconds |
 |
 |
ENVIRONMENT
|
 |
| Environment Ambient |
3,500 meters max. elevation, 0-95% humidity (Non condensing water), 0-40 deg c |
 |
| Environment Audible |
< 40dBA ( 1 meter from surface) |
 |
| ShowOrder |
130 |
|
Click here to return
|
|
|
March 2011 |

GENERAL INFORMATION
|
 |
| Model Type |
KING PRO |
 |
| Model Name |
KIN-1500AP |
 |
 |
AC INPUT
|
 |
| AC Input Capacity on Battery |
1500VA |
 |
| AC Input Voltage |
(+/-) 25% at line input |
 |
| AC Input Frequency |
50 or 60 Hz+/-10% (auto sensing) |
 |
 |
AC OUTPUT
|
 |
| AC Output Voltage |
Simulated sine ware at 100V or 110V/115V/120V or 220V/230V/240V +/-5% |
 |
| AC Output Frequency |
50 or 60 Hz +/- 0.5% |
 |
| AC Output Voltage Regulation |
AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 13% below input voltage if +9% to +25% of nominal |
 |
| AC Output Transfer |
2/4 milliseconds, including detection time |
 |
 |
PROTECTION
|
 |
| Protection Spike |
320 Joules, 2ms |
 |
| Protection EMI/RFI |
10dB at 0.15 MHz, 50 dB at 30 MHz |
 |
| Protection Overload |
UPS automatic shutdown if overload exceeds 110% nominal at 60 sec and 130% at 3 sec |
 |
| Protection Unit |
Fuse for overload & short circuit protection |
 |
| Protection 10 BaseT |
Network (UTP, RJ-45) compatible jacks |
 |
| Protection Short Protection |
UPS output cut off immediately or input fuse protection |
 |
 |
BATTERY
|
 |
| Battery Type |
Sealed, Maintenance-free lead acid, with 3 - 6 years typical lifetime |
 |
| Battery Typical |
4 hours (to 90% of full capacity) |
 |
| Battery Protection |
Automatic self-test & discharge protection, replace battery indicator |
 |
| Battery Run Time |
70 - 80 minutes |
 |
BATTERY BACKUP TIME
Battery Backup Time 7 Minutes
Full Load
Battery Backup Time
Half Load 15 Minutes
|
PHYSICAL
|
 |
| Physical Weight kgs Tower |
15.6 |
 |
| Physical Weight lbs Tower |
(34.3lb) |
 |
| Physical Dimension mm Tower |
130x382x201 |
 |
| Physical Dimension inch Tower |
(5.1 |
 |
 |
 |
ALARM
|
 |
| Alarm Battery Backup |
Slow beeping sound (about 0.47 Hz) |
 |
| Alarm Battery Low |
Rapid beeping sound (about 1.82Hz) |
 |
| Alarm Overload |
Continue beeping sound |
 |
 |
INTERFACE
|
 |
| Interface RS-232 |
Bi-directional communication port |
 |
 |
ENVIRONMENT
|
 |
| Environment Ambient |
3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40 deg c |
 |
| Environment Audible |
<40dBA (1 meter from surface) |
 |
| ShowOrder |
19 |
|
Click here to return
|
|
|
|
<< Start < Prev 161 162 163 164 165 166 167 168 169 170 Next > End >>
|